ZONESUN
ZONESUN ZS-FAL180Z3 Automatic Test Tube Filling, Capping & Labeling Line
ZONESUN ZS-FAL180Z3 Automatic Test Tube Filling, Capping & Labeling Line
픽업 사용 가능 여부를 로드할 수 없습니다.
Automatic Reagent Tube Filling, Capping and Labeling
The ZONESUN ZS-FAL180Z3 automatic test tube filling, capping and labeling line integrates tube sorting, peristaltic liquid filling, cap feeding, screw tightening and label application. Container-specific rotary tooling positions tubes through the process, while a coordinated conveyor transfers them to the labeling station.
The listed setup is configured for 25 mL filling and about 30 tubes/min, depending on liquid and tube dimensions. Tube size, cap dimensions, tubing and label specifications must be confirmed for each project. The peristaltic system keeps liquid inside the tubing rather than in contact with the pump mechanism; it does not establish aseptic performance on its own.
Key Features
- Integrated tube packaging: Feeding, filling, capping and labeling in a coordinated workflow.
- Peristaltic dosing: Replaceable tubing supports product-path changeover when compatible materials are selected.
- Automatic tube and cap feeding: Vibratory sorting and transfer components organize incoming parts.
- Customized rotary tooling: Matches tube geometry and station positions.
- Dedicated labeling station: Adjustable settings coordinate tube handling and label application.
- Touchscreen controls: Provide parameter setting and operating-status access.
Published Specifications
|
Machine Model |
ZS-FAL180Z3 |
|
Voltage |
230V/220V 50-60Hz |
|
Machine Pump |
Peristaltic pump |
|
Machine Power |
2KW (filling and capping) 1.25KW (labeling) |
|
Bottle Diameter |
Customized |
|
Filling Range |
25ml |
|
Bottle Height |
Customized |
|
Cap Diameter |
Customized |
|
Working Speed |
30 bottles/min(depends on liquid and tube size) |
|
Machine Size |
1600*1500*1700mm (filling and capping) 2400*850*1600mm (labeling) |
|
Machine Weight |
500kg (filling and capping) 250kg (labeling) |
|
Package Size |
1650*1550*1760mm (filling and capping) 2500*900*1760mm (labeling) |
|
Package Weight |
520kg (filling and capping) 270kg (labeling) |
Configuration note: The parameter table lists 220/230 V, while the current selectable variants are 110 V and 220 V. Confirm voltage, frequency, total connected load and pneumatic requirements in the approved quotation. The 25 mL figure describes the listed configuration rather than a universal filling range.

Automatic Tube Filling, Capping and Labeling
The integrated line combines tube feeding, peristaltic liquid dosing, cap feeding, screw capping and labeling. Product stays inside the pump tubing rather than contacting the pump mechanism; cleanliness still depends on compatible materials, preparation and operating procedures.

Tube Applications and Published Parameters
The image illustrates capped test and reagent tubes. The listed configuration uses peristaltic pumps, a 25 mL dose and about 30 tubes/min depending on liquid and tube size. Tube diameter, height and cap size are customized. The legacy image table shows a different model name; this product listing identifies ZS-FAL180Z3, so confirm the final technical proposal for the supplied build.

Filling/Capping and Labeling Stations
The diagram identifies tube and cap bowl feeders, a vibrating tube-feeding section, filling nozzle, cap placement and tightening stations, rotary table and controls. The labeler includes a reel, conveyor, sensor, height adjustment and control panel. Align station settings to the actual tube, cap and label.

PLC Touchscreen Controls
The filling/capping and labeling touchscreens provide access to working parameters and machine status. Set each station for the approved product and container, then verify the complete sequence during setup.

Vibratory Feeders and Peristaltic Pumps
Separate feeder controls coordinate tube sorting, cap sorting and tube transfer. Peristaltic pumps move product inside tubing that can be replaced for changeover. They do not by themselves guarantee sterile or contamination-free output.

Rotary Indexing and Tube Detection
The customized rotary table positions tubes through filling, cap feeding, cap placement and screw tightening. A photoelectric sensor detects tubes for coordinated operation. Confirm the tooling, cap mechanism and control sequence using actual samples.

Rotary Filling and Capping Layout
The annotated view shows the filling point, cap feeding, cap tightening and customized rotary plate. Container-specific fixtures support positioning; different tube sizes may require change parts.

Labeling Drive and Integrated Line View
The label rotation/drive speed can be adjusted at the controller. Coordinate tube transport and label application with the filling/capping station to establish stable operation.

Complete Line Views
These views show the assembled line from different angles. Confirm actual working dimensions, maintenance clearances and upstream/downstream interfaces against the approved layout; individual machine dimensions are not a complete installation footprint.
Frequently Asked Questions
Which tubes and liquids can the line handle?
The listed application is compatible liquid solutions and reagents in capped tubes. Send tube and cap samples, liquid properties and label drawings so ZONESUN can assess feeding, material compatibility, dosing and tooling.
Is 25 mL the only available volume?
It is the published dose for this configuration. A different volume requires confirmation of pump settings, tubing, nozzle and cycle time. Provide your minimum and maximum doses for evaluation.
What output can I expect?
The stated speed is about 30 tubes/min and depends on liquid and tube size. Feeding reliability, dose, cap design and label application also affect output. Confirm performance through testing with your parts and liquid.
Does peristaltic filling guarantee sterility?
No. The liquid stays inside tubing without contacting the pump mechanism, but product treatment, component cleanliness, environment and operating procedures determine process hygiene. Specify any aseptic or validated-process requirements separately.
Can different tube sizes use the same tooling?
The rotary plate, feeder tracks and cap-handling parts are customized. Different tubes or caps may require change parts and setup adjustments. Send all formats before the line is configured.
What information is needed for installation and commissioning?
Provide factory layout, available voltage and frequency, compressed-air supply, required interfaces and product samples. Confirm total line dimensions, service clearances, utilities, test criteria and installation/training scope in the quotation.
Request a Custom Tube Filling and Packaging Line
Send ZONESUN your solution or reagent properties, tube and cap samples, filling volume, label size and roll specification, required tubes/min and factory layout. Include available utilities and any process-validation requirements. Our team can assess dosing, feeding, capping, labeling and change parts, then prepare a coordinated line proposal with agreed acceptance-test conditions.